How to Choose Variable Pipettes for Your Lab

How to Choose Variable Pipettes for Your Lab

How to Choose Variable Pipettes for Your Lab
Variable pipettes let you set different transfer volumes within a specified range. A lab that adds 2 µL of enzyme, dispenses 150 µL of reagent and transfers 3 mL of buffer will need different pipettes for those jobs. Start with the volumes your protocols call for most often, then compare accuracy, precision, tip compatibility and cleaning requirements.
Match the pipette range to your protocols
Use these common adjustable ranges as a starting point. Exact limits vary by model. One millilitre (mL) equals 1,000 microlitres (µL).
Example volume range    Typical laboratory tasks
0.2–2 µL    Adding very small volumes of enzyme or concentrated reagent
0.5–10 µL or 2–20 µL    Preparing small reaction mixes or adding reagents to tubes
10–100 µL or 20–200 µL    Dispensing reagents, preparing dilutions or transferring aliquots
100–1,000 µL    Transferring samples or adding buffer in sub-millilitre volumes
0.5–5 mL or 1–10 mL    Transferring larger volumes of compatible buffers or diluents
When two ranges overlap, compare the manufacturer’s accuracy and precision specifications at the volume you actually use. For example, if you routinely dispense 20 µL, compare a 2–20 µL pipette and a 20–200 µL pipette at 20 µL against your method’s tolerances. Keep every setting within the instrument’s stated range.
Choose the pipette format and tips for your workflow
A single-channel pipette suits individual tubes or wells. A multichannel pipette can speed up repeated dispensing into compatible microplates. If several people share a pipette or use it for long periods, check that the volume display is easy to read and that the plunger and tip ejector are comfortable to operate.
Confirm tip compatibility with the specific model before ordering. Two tips can have the same capacity and fit differently on the pipette cone. A poor seal can cause leakage or inconsistent aspiration. If your procedure requires filtered or low-retention tips, check that compatible versions are available in the size you need.
Check cleaning and calibration requirements
For an autoclavable or semi-autoclavable pipette, check the manufacturer’s instructions for which components can be autoclaved, whether they need to be disassembled and which cycle to use.
Ask what calibration documentation comes with the instrument and how you can arrange future verification or servicing. If your lab uses the same pipette for several protocols, make sure its performance meets the tolerances for each method.
Explore variable pipettes at Lab Buddy
Lab Buddy lists options for small-volume work, routine transfers and larger microlitre volumes.
●    0.5–10 µL single-channel semi-autoclavable pipettor
●    20–200 µL Gilson-type variable autoclavable pipettor
●    100–1,000 µL single-channel semi-autoclavable pipettor
Check the product pages for availability. If you need a different volume range or help matching tips to a specific pipette, contact Lab Buddy with the volumes you routinely transfer